Related Experiment Video
Updated: Jul 17, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Determination of catecholamines by flow-injection analysis and high-performance liquid chromatography with
Edyta Nalewajko1, Aneta Wiszowata, Anatol Kojło
1Institute of Chemistry, University of Białystok, ul. Hurtowa 1, 15-399 Białystok, Poland.
Abstract:
A chemiluminescence (CL) detection of catecholamines [norepinephrine (NE), epinephrine (E), dopamine (DA) and L-dopa (LD)] is described for the flow-injection (FI) and high-performance liquid chromatographic (HPLC) determination of these compounds. The detection method is based on the inhibition effect of catecholamines (CAs) on the CL reaction of luminol with iodine in the alkaline medium. The proposed FI method allows the determination of CAs in pharmaceutical preparations for the purpose of drug quality control. The calibration curves show good linearity in the concentration range of: 1.1-20.0 microg l(-1) (NE), 0.5-5.0 microg l(-1) (E), 0.6-9.0 microg l(-1) (DA) and 0.6-10.0 microg l(-1) (LD). The limits of detection (defined as a signal-to-noise ratio of 3) are: 0.34 microg l(-1) (NE), 0.15 microg l(-1) (E) and 0.18 microg l(-1) (DA, LD). The HPLC procedure was successfully applied for the determination of catecholamines (NE, E, DA) in human urine after solid-phase extraction (SPE). In a simple run time CAs can be determined in 20 min. The chromatographic linear ranges are: 5.0-72.0 microg l(-1) (NE), 5.0-48.0 microg l(-1) (E) and 5.0-96.0 microg l(-1) (DA). The limits of detection for three urinary CAs are: 0.71 microg l(-1) (NE), 0.26 microg l(-1) (E) and 0.73 microg l(-1) (DA).
More Related Videos
11:26Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II