Packing performance of GDC 360 degrees coils in intracranial aneurysms: a comparison with complex orbit coils and
1Department of Radiology, St. Elisabeth Ziekenhuis, Tilburg, The Netherlands. radiol@knmg.nl
Background And Purpose:
The purpose of this study was to compare obtained packing densities of aneurysms treated with the newly introduced GDC 360 degrees coils with packing densities of aneurysms treated with either complex Orbit/Trufill coils or helical GDC 10 coils.
Patients And Methods:
Twenty-two aneurysms in 20 patients were coiled with GDC 360 degrees coils. For each of the 22 aneurysms coiled with GDC 360 degrees coils, 2 volume-matched controls treated with either complex Orbit/Trufill coils or helical GDC coils were identified from our data base. The packing of these matched controls was compared with the calculated packing of the 22 aneurysms treated with GDC 360 degrees coils.
Results:
There was no difference in mean aneurysm volume between aneurysms treated with any of the 3 types of coils (P = .9). Mean packing of 22.1% of aneurysms treated with GDC 360 degrees coils was significantly lower than mean packing of 30.3% of aneurysms treated with complex Orbit/Trufill coils (P = .0015). Mean packing of 22.1% of aneurysms treated with GDC 360 degrees coils was not different from mean packing of 21.6% of aneurysms treated with helical GDC 10 coils (P = .81).
Conclusion:
The use of complex-shaped GDC 360 degrees coils does not lead to increased packing in comparison with that of helical GDC 10 coils. The use of complex Orbit/Trufill coils results in significantly higher packing than that of both GDC 360 degrees coils and helical GDC 10 coils.
Related Concept Videos
Increased Intracranial Pressure l: Introduction
Aneurysm I: Introduction
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Aneurysm II: Clinical Manifestations and Diagnostic Studies
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...