Calibration transfer between two near-infrared spectrometers based on a wavelet packet transform
1College of Chemistry, Sichuan University, Chengdu, Sichuan, PR China.
A new algorithm, Wavelet Packet Transform Standardization (WPTS), enables accurate spectral transfer between near-infrared spectrometers. This method offers comparable performance to existing techniques with simpler variable selection and lower computational costs.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Chemometrics
Background:
- Near-infrared (NIR) spectroscopy is widely used for chemical analysis.
- Spectral variability between instruments necessitates standardization for accurate data transfer.
- Existing methods for calibration transfer can be complex and computationally intensive.
Purpose of the Study:
- To propose a novel standardization algorithm, WPTS, for spectral transfer between NIR spectrometers.
- To evaluate the performance of WPTS against existing calibration transfer methods.
- To demonstrate a simpler and computationally efficient approach to spectral standardization.
Main Methods:
- Development of the Wavelet Packet Transform Standardization (WPTS) algorithm.
- Utilizing entropy criteria and wavelet packet transform (WPT) for optimal WPT-tree generation.
- Establishing a transfer matrix based on selected WPT-tree nodes.
- Validation using spectra from standardization samples measured on two different NIR spectrometers.
Main Results:
- WPTS successfully transfers spectra between NIR spectrometers, enabling data to be treated as if measured on the target instrument.
- The proposed WPTS achieves transfer performance comparable to the best existing method (WTS1).
- WPTS outperforms WTS2 and classical PDS methods in transfer accuracy.
- WPTS employs a simpler variable selection technique and exhibits lower computational cost.
Conclusions:
- WPTS provides an effective and efficient method for spectral standardization in NIR spectroscopy.
- The algorithm simplifies the process of calibration transfer while maintaining high accuracy.
- WPTS offers a valuable alternative for researchers and practitioners dealing with multi-instrument NIR data.
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
IR Spectrometers
Calibration Curves: Correlation Coefficient
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...