Related Experiment Video
Updated: Jul 17, 2026

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Measuring free metal ion concentrations in multicomponent solutions using the Donnan membrane technique
Erwin J J Kalis1, Liping Weng, Erwin J M Temminghoff
1Department of Soil Quality, Wageningen University, Wageningen, The Netherlands.
The Donnan membrane technique (DMT) accurately measures free metal ion concentrations in complex samples. Its dynamic mode can reduce equilibrium time when labile ligands are present.
Area of Science:
- Environmental Chemistry
- Analytical Chemistry
- Geochemistry
Background:
- Accurate measurement of free metal ion concentrations is crucial for understanding metal behavior in various environmental matrices.
- The Donnan membrane technique (DMT) offers simultaneous measurement of multiple free metal ions but requires further calibration and validation.
- Previous applications of DMT have included surface waters, soil solutions, and manure, yet fundamental characterization is lacking.
Purpose of the Study:
- To validate the Donnan membrane technique (DMT) for measuring free metal ion concentrations in the presence of diverse ligands.
- To assess the applicability and efficiency of the dynamic mode of the DMT.
- To compare results from laboratory and field-based DMT applications.
Main Methods:
- Utilized the Donnan membrane technique (DMT) in both laboratory and field settings.
- Investigated metal complexation with synthetic ligands (nitrilotriacetic acid, diglycolic acid) and natural organic ligands (fulvic acid, humic acid).
- Evaluated the dynamic mode of the DMT, comparing equilibrium times with and without labile ligands.
Main Results:
- Demonstrated high agreement between calculated and measured free metal ion concentrations across various pH values and ligand types.
- Observed consistent results between laboratory and field DMT measurements.
- Confirmed that equilibrium time is reduced in the presence of labile ligands, especially when using the dynamic DMT procedure.
Conclusions:
- The Donnan membrane technique (DMT) is a reliable method for quantifying free metal ion concentrations in complex environmental samples.
- The dynamic mode of the DMT effectively reduces measurement time when labile ligands are present.
- DMT calibration and validation are essential for accurate speciation analysis in environmental research.
More Related Videos
09:18Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Related Concept Videos
Potentiometry: Membrane Electrodes
Dialysis
Extraction: Advanced Methods
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...