Reliability of knee flexor peak torque measurements from a standardized test protocol on a Kin/Com dynamometer
1Physiotherapy Department, Health Sciences Centre, Winnipeg, Manitoba, Canada.
Archives of Physical Medicine and Rehabilitation
|January 1, 1992
Summary
This study found that a specific test protocol using a Kin/Com dynamometer reliably measures peak torque for knee flexor muscles during resisted-muscle shortening and lengthening. The protocol demonstrates high test-retest reliability for both concentric and eccentric contractions at common testing velocities.
Area of Science:
- Biomechanics
- Kinesiology
- Sports Medicine
Background:
- Assessing knee flexor muscle strength is crucial in clinical and sports settings.
- The Kin/Com dynamometer is a common tool for measuring muscle torque.
- Establishing reliable testing protocols is essential for accurate strength assessment.
Purpose of the Study:
- To evaluate the test-retest reliability of a specific protocol for measuring peak knee flexor torque.
- To assess reliability at two different angular velocities (30°/sec and 180°/sec).
- To determine reliability for both concentric (resisted-muscle shortening) and eccentric (resisted-muscle lengthening) contractions.
Main Methods:
- 11 healthy women performed tests measuring peak torque of knee flexors using a Kin/Com dynamometer.
- Measurements were taken in a sitting position at 30°/sec and 180°/sec, including resisted-muscle shortening (RMS) and resisted-muscle lengthening (RML) cycles.
- Subjects repeated the tests within a single session and again one week later.
- Intraclass correlation coefficients (ICCs) were calculated to assess reliability.
Main Results:
- High within-session reliability was observed, with ICCs ranging from 0.92 to 0.98 across velocities and contraction types.
- Between-session reliability was generally lower but still strong, with ICCs ranging from 0.75 to 0.90.
- Peak torque measurements for both RMS and RML demonstrated good to excellent reliability.
Conclusions:
- The evaluated test protocol provides a reliable method for measuring peak knee flexor torque.
- High reliability was confirmed for both concentric and eccentric contractions at 30°/sec and 180°/sec.
- This protocol can be confidently used in research and clinical practice for assessing knee flexor strength.