Accurate modelling of the radiation output of a medical linear accelerator is important for radiotherapy treatment planning. The major challenge is the adjustment of the model to a specific treatment unit. One approach is to use a multiple-source model containing a set of physical parameters. In this work, the parameters were derived from standard beam data measurements using optimization methods. The source model used includes sub-sources for bremsstrahlung radiation from the target, extra-focal photon radiation and electron contamination. The cost function includes a gamma error measure between measurements and current dose calculations. The procedure was applied to six beam data sets (6 MV to 23 MV) measured with accelerators from three vendors, but the results focus primarily on Varian accelerators. The obtained average gamma error (1%, 1 mm) between dose calculations and measurements used in optimization was smaller than 0.7 for each studied treatment beam and field size, and a minimum of 83% of measurement points passed the gamma < 1 criterion. For experiments made at different SSDs and for asymmetric fields, the average gamma errors were smaller than 1.1. For irregularly shaped MLC apertures, the differences in point doses were smaller than 1.0%. This work demonstrates that the source model parameters can be automatically derived from simple measurements using optimization methods. The developed procedure is applicable to a wide range of accelerators, and has an acceptable accuracy and processing time.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Methods of Medium Optimization
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...