Related Experiment Video
Updated: Jul 16, 2026

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Calibration of CE-QUAL-W2 for a monomictic reservoir in a monsoon climate area
1Department of Environmental Engineering, Chungbuk National University, 12 Gaeshin-dong Heungduk-ku, Cheongju City, Korea. schung@chungbuk.ac.kr
Abstract:
The impact of inflow mixing on reservoir stratification is significant for reservoirs situated in a monsoon climate area. It cause difficulty in the calibration of a two-dimensional hydrodynamic and water quality model, CE-QUAL-W2 that was recently adopted for a real-time turbidity monitoring and modelling system (RTMMS) for a reservoir in Korea. This paper presents a systematic calibration and verification processe of the model for the reservoir. A sensitivity analysis showed that wind sheltering, Chezy, and sediment heat exchange coefficients are most sensitive to stratification structure. Inflow temperature was very sensitive during a year of normal precipitation, but it is not significant during a year of drought. Residual analysis revealed that the model has shortcomings in the simulation of water temperature near the metalimnetic zone without calibration. After calibration, however, the absolute mean errors between observed and simulated values were placed within 0.116-1.190 degrees C. Its performance was maintained under heavy flood events during the verification stage, which implies that the model is ready to use for the simulation of turbidity plume in the RTMMS under various hydrologic conditions. The suggested model calibration strategy and relevant results may be adopted for other reservoirs located in a monsoon climate area.
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Precipitation and Co-precipitation
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...

