Corona-charged aerosol detection in supercritical fluid chromatography for pharmaceutical analysis
C Brunelli1, T Górecki, Y Zhao
1Pfizer Analytical Research Centre, Ghent University, Ghent, Belgium.
Abstract:
In this paper we describe the coupling of a corona-charged aerosol detector (CAD) to packed column supercritical fluid chromatography (pSFC). The CAD can be coupled to pSFC by connecting the outlet of the back pressure regulator (BPR) directly to the inlet of the detector. To reduce the noise and increase the reproducibility, the transfer line (1 m x 0.25 mm i.d. stainless steel) was placed in a thermostatic bath at 45 degrees C. Limits of detection (LODs) ranged from 3 to 11.5 ng loaded on column, with an average value of 4.5 ng (from 0.6 to 2.3 mg/L, with an average value of 0.9 mg/L for 5 microL injection). To reduce differences in response at different mobile-phase compositions, mobile-phase flow compensation was performed by placing a T-piece before the BPR. In this way, the differences in response were significantly reduced from a factor of 2-3 to a factor of 1.2-1.7. Compared to CAD application without flow compensation, the average LOD was higher by a factor of approximately 1.8. However, the nearly uniform response in gradient analysis with mobile-phase flow compensation far outweighed the slight increase in the LOD. The performance of the pSFC-CAD combination was illustrated by the analysis of selected pharmaceutically related compounds. In addition, a comparison with UV detection was made. Measurement of analytes at a relative concentration of 0.05% versus the main component was demonstrated.
More Related Videos
08:33Use of Capillary Aerosol Generator in Continuous Production of Controlled Aerosol for Non-Clinical Studies
Published on: April 12, 2022
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...