One-year mean follow-up of 41 patients treated with bifurcation stenting

Nauman Naseer1, Raja Varma, Wilbert S Aronow

  • 1Cardiology Division, Department of Medicine, Westchester Medical Center/New York Medical College, Valhalla, NY 10595, USA.

Insights

Coronary artery stenting of bifurcation lesions showed favorable outcomes, with low rates of major adverse cardiac events including myocardial infarction and restenosis after 12 months. Crushing stent technique was most commonly used.

Area of Science:

  • Interventional Cardiology
  • Cardiovascular Medicine
  • Biomedical Engineering

Background:

  • Bifurcation coronary artery lesions present unique challenges for percutaneous coronary intervention.
  • Optimal stent deployment strategies are crucial to minimize adverse events in these complex anatomies.

Purpose of the Study:

  • To evaluate the safety and efficacy of various stenting techniques for bifurcation coronary artery lesions.
  • To assess the mid-term clinical outcomes following stent implantation in this patient cohort.

Main Methods:

  • Retrospective analysis of 41 patients undergoing stenting for bifurcation coronary artery lesions.
  • Utilized techniques included crushing stent (80%), T stent (15%), kissing stent (2%), and side branch angioplasty (2%).
  • Mean follow-up duration was 12 months.

Main Results:

  • No deaths occurred during the follow-up period.
  • Low incidence of major adverse cardiac events: 2% myocardial infarction, 7% stent occlusion, 7% restenosis, and 10% target lesion revascularization.
  • Overall, 15% experienced myocardial infarction, target lesion revascularization, or death.

Conclusions:

  • Stenting of bifurcation coronary artery lesions, particularly with the crushing technique, demonstrates acceptable safety and efficacy.
  • The study suggests favorable mid-term outcomes with low rates of major adverse cardiac events in patients treated for bifurcation lesions.

Related Concept Videos

Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices07:21

Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices

Here, we describe the technique for the microsurgical creation of giant bifurcation aneurysms in rabbits for the evaluation of endovascular devices.
1.0K
4D Printed Bifurcated Stents with Kirigami-Inspired Structures06:52

4D Printed Bifurcated Stents with Kirigami-Inspired Structures

Using a 3D printer, a shape memory polymer filament is extruded to form a branched tubular structure. The structure is patterned and shaped such that it can contract into a compact form once folded and then return to its formed shape when...
8.5K
Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation04:42

Treating Low Back Pain in Failed Back Surgery Patients with Multicolumn-lead Spinal Cord Stimulation

This paper presents a method that uses spinal cord stimulation with a multicolumn lead to treat neuropathic low back pain in failed back surgery...
15.1K
Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents06:55

Fabrication of Small Caliber Stent-grafts Using Electrospinning and Balloon Expandable Bare Metal Stents

In the protocol, we present a method to manufacture a small caliber stent-graft by sandwiching a balloon expandable stent between two electrospun nanofibrous polyurethane...
9.4K
A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis04:30

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis

A model of stent implantation in mouse carotid artery is described. Compared to other similar methods, this procedure is very rapid, simple and accessible, offering the possibility to study in a convenient way the vascular wall reaction to different drug-eluting stents and the molecular mechanisms of...
26.2K
Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model09:46

Imaging In-Stent Restenosis: An Inexpensive, Reliable, and Rapid Preclinical Model

This video demonstrates how to use a preclinical inexpensive and reliable model to study pathobiological and pathophysiological processes of in-stent restenosis development. Longitudinal in vivo monitoring using OCT (Optical Coherence Tomography) and analysis of OCT images are also...
14.3K