Evaluation of tongue coating indices
T Lundgren1, A Mobilia, H Hallström
1Department of Periodontics, School of Dentistry, Loma Linda University, Loma Linda, CA, USA. tord.lundgren@ucsf.edu
Aim:
The purpose of this study was to determine inter-examiner reproducibility of two modified Winkel tongue coating indices and to study the relationship between each of these two indices and the amount of tongue coating as determined by wet weight of scrapings from the dorsum of the tongue.
Materials And Methods:
Twenty-five participants were selected for the study from among dental students. The selection was made to assure that a wide range of degrees of tongue coating were represented. Two independent examiners scored the tongue coatings using the two modified Winkel tongue coating indices (mWTCI 1 + 2 and mWTCI 2). After completion of index recordings, tongue scrapings were performed by one of the examiners.
Results:
Inter-examiner reproducibility of mWTCI 1 + 2 and mWTCI 2 using Pearson's coefficients of correlation amounted to r = 0.48 and 0.93 respectively. Overall, mWTCI 2 showed higher correlations to wet weight of tongue scrapings than mWTCI 1 + 2.
Conclusion:
The mWTCI 2 was found to be highly reproducible and also valid as related to wet weight of tongue scrapings. This index would seem suitable for further studies on tongue coatings; effect of tongue cleaning; and rate of reformation of coatings after cleaning.
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
The Tongue and Taste Buds
Tongue
Anatomical Position in the Oral Cavity
The tongue is located within the oral cavity, also known as the mouth. It is attached to the floor of the mouth by a fold of mucous membrane called the...
Taste Buds and Receptors
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...