An intercomparison of neutron dosimeters and detectors for in-containment dosimetry
L E Auman1, W H Miller, C C Graham
1Department of Nuclear Engineering, University of Missouri, Columbia 65211.
Abstract:
To improve the methodology for assessing neutron dose at Union Electric's Callaway Nuclear Power Plant, an intercomparison of neutron detectors and dosimeters was performed. Seven different neutron detectors and dosimeters were tested in four different neutron fields utilizing facilities at the Missouri University Research Reactor and at the Southwest Radiation Calibration Center at the University of Arkansas. In general, all results agree within a factor of 2 in predicting the neutron dose equivalent. It was concluded that measurements of dose in containment should utilize the Tissue-Equivalent Proportional Counter (TEPC), the Bonner-sphere system, and the proton recoil spectrometer to accurately assess the neutron dose. These data can then be used to provide correction factors for more traditionally used dosimeters in containment, such as thermoluminescent dosimeters and survey meters.