Related Experiment Video
Updated: Jul 16, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Application of amplitude-based and slope-based algorithms to determine beat-to-beat finger arterial compliance during
R Raamat1, J Talts, K Jagomägi
1Department of Physiology, University of Tartu, Tartu, Estonia. raamat@ut.ee
Abstract:
Beat-to-beat finger arterial compliance C is calculated applying two different estimates. The amplitude-based algorithm C(amplit) = DeltaV/DeltaP determines compliance as a ratio of finger volume and pressure pulses, whereas the slope-based technique C(slope)=dV/dP is based on the calculation of the slope of the pressure-volume relationship from the first derivatives dV/dt and dP/dt of the recorded volume and pressure pulses at the point of their maximum slope. The finger arterial pressure and volume changes in 11 healthy volunteers during two successive handgrips were recorded by applying the Finapres monitor and the UT9201 physiograph, respectively. The latter instrument automatically keeps counter pressure in the measuring cuff equal to the mean intra-arterial pressure (transmural pressure P(transm) = 0). The results of the study demonstrate that both compliance estimates gave analogous responses to light physical exercise (r = 0.94, p < 0.002). At the same time, the values of C(slope) were systematically higher than those for C(amplit) (the slope of the regression line equalled 1.11). Even at P(transm) = 0, a variation of 13mmHg in the pulse pressure caused an 8% modulation in C(amplit) (p = 0.03). The slope-based estimate was less sensitive to pulse pressure changes.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
