Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents
Edzard Wiener1, Klaus Woertler, Gregor Weirich
1Department of Radiology, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany. ewiener@roe.med.tu-muenchen.de
Abstract:
Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5T. Dynamic MR-studies over 11h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5mmol/L contrast solution. Simultaneous measurements of T(1) and T(2) were performed every 30min using a high-spatial-resolution "MIX"-sequence. T(1), T(2) and DeltaR(1), DeltaR(2) profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11h of diffusion. The absolute DeltaR(2)-effect in cartilage is at least as large as the DeltaR(1)-effect for all contrast agents. Maximum changes were 5-12s(-1) for DeltaR(1) and 8-15s(-1) for DeltaR(2). This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, DeltaR(2) can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than DeltaR(1).
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT