Related Experiment Video
Updated: Jul 16, 2026

Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Calibration of a passive sampler for both gaseous and particulate phase polycyclic aromatic hydrocarbons
1Laboratory for Earth Surface Processes, College of Environmental Sciences, Peking University, Beijing 100871, China. taos@urban.pku.edu.cn
Abstract:
A novel passive air sampler was designed and tested that individually collects the gaseous and particulate phase polycyclic aromatic hydrocarbons (PAHs) in air. The sampler was calibrated against a conventional active sampler in an indoor environment. A PUF (polyurethane foam) disk and a piece of GFF (glass fiber filter) were installed in a sampling shelter for collecting gaseous and particulate phase PAHs, respectively. The passive samplers were deployed in seven indoor locations for 86 days. Six times during this period, 24-h conventional active sampling was conducted for calibration at an average interval of 17-days. Principle component analysis showed that the measured congener profile compositions were totally different between the gaseous and particulate phase PAHs, but similar between the passive and the active samples. This suggested that gaseous and particulate phase PAHs were primarily trapped by the PUF disk and GFF, respectively. Linear relationships between the passively and the actively measured and log-transformed concentrations were derived for calibration of both gaseous and particulate phase PAHs. The uptake rates of the sampler were 0.10 +/- 0.014 m3/d and 0.007 +/- 0.001 m3/d for gaseous and particulate phase PAHs, respectively. The rates were significantly lower than those reported in the literature using similar PUF samplers, mainly because of the special design with limited air circulation.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...