Objective:
The purpose of this study was to compare the accuracy of radiographers with that of radiologists in the interpretation of CT colonographic images.
Materials And Methods:
Four observers (a radiologist, a radiologist in training, and two radiographers) evaluated 145 data sets using a primary 3D approach. The radiographers were part of our CT colonography work group and underwent training that consisted of 20 cases. The reference standard was optical colonoscopy with second-look colonoscopy for discrepant lesions > or = 10 mm in diameter. Mean sensitivities per patient and per polyp stratified for size (any size, > or = 6 mm, and > or = 10 mm) was determined for the radiologists and radiographers. Specificity was determined on a per-patient basis.
Results:
At colonoscopy in 86 of 145 patients, a total of 317 polyps were found (60 polyps > or = 6 mm in 26 patients and 31 polyps > or = 10 mm in 18 patients). No statistically significant differences were found in detection rates between radiologists and radiographers. Sensitivities for patients with a lesion of any size (66% for radiologists vs 65% for radiographers), > or = 6 mm (81% vs 87%), and > or = 10 mm (both 78%) were similar for all observers. On a per-polyp basis, detection rates were equivalent regardless of polyp size (47% vs 40%), for lesions > or = 6 mm (71% vs 65%), and for lesions > or = 10 mm (69% vs 66%). Mean specificities were similar among patients without lesions (31% vs 30%), patients without lesions > or = 6 mm (71% vs 67%), and patients without lesions > or = 10 mm (93% vs 93%).
Conclusion:
Radiographers with training in CT colonographic evaluation achieved sensitivity and specificity in polyp detection comparable with that of radiologists. Radiographers can be considered reviewers in the evaluation of CT colonographic images.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...