The hemostatic history of a 15-month-old child implanted with a Berlin heart left ventricular assist device

Brad L Steenwyk1, James K Kirklin, William Q Gurley

  • 1Department of Anesthesiology, The University of Alabama at Birmingham, Birmingham, AL 35294-2172, USA.

Anesthesia and Analgesia
|February 22, 2007
PubMed

Insights

Placement of a Berlin Heart ventricular assist device rapidly induced hypercoagulability in a pediatric patient, requiring significant blood products for hemostasis despite aggressive anticoagulation. Careful management is crucial for patient safety.

Area of Science:

  • Cardiovascular Surgery
  • Pediatric Cardiology
  • Hematology

Background:

  • Left ventricular assist devices (LVADs) like the EXCOR Berlin Heart are critical for pediatric end-stage heart failure.
  • Understanding hemostatic changes is vital for managing patients awaiting heart transplantation.

Observation:

  • A 15-month-old child received an EXCOR Berlin Heart LVAD prior to heart transplantation.
  • Hemostatic status was monitored throughout the peri-operative period.

Findings:

  • Rapid development of hypercoagulability was observed, characterized by increased plasmatic and platelet-mediated coagulation kinetics and strength.
  • This hypercoagulable state persisted for several weeks post-implantation.
  • The patient experienced no thrombotic complications but required substantial blood product support to maintain hemostasis due to aggressive anticoagulation.

Implications:

  • Anesthetic and surgical management protocols for Berlin Heart patients must account for potential hypercoagulability.
  • Careful consideration of anticoagulant therapy is essential to balance bleeding risk and thrombotic prevention.
  • Optimizing hemostatic management is critical for improving patient safety and outcomes in pediatric LVAD recipients.