Related Experiment Video
Updated: Jul 16, 2026

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Carotid artery pulse wave time characteristics to quantify ventriculoarterial responses to orthostatic challenge
Koen D Reesink1, Evelien Hermeling, M Christianne Hoeberigs
1Department of Biophysics, CARIM, Maastricht University, PO Box 616, 6200 MD Maastricht, The Netherlands. k.reesink@bf.unimaas.nl
Abstract:
Central blood pressure waveforms contain specific features related to cardiac and arterial function. We investigated posture-related changes in ventriculoarterial hemodynamics by means of carotid artery (CA) pulse wave analysis. ECG, brachial cuff pressure, and common CA diameter waveforms (by M-mode ultrasound) were obtained in 21 healthy volunteers (19-30 yr of age, 10 men and 11 women) in supine and sitting positions. Pulse wave analysis was based on a timing extraction algorithm that automatically detects acceleration maxima in the second derivative of the CA pulse waveform. The algorithm enabled determination of isovolumic contraction period (ICP) and ejection period (EP): ICP=43+/-8 (SD) ms (4-ms precision), and EP=302+/-16 (SD) ms (5-ms precision). Compared with the supine position, in the sitting position diastolic blood pressure (DBP) increased by 7+/-4 mmHg (P<0.001) and R-R interval decreased by 49+/-82 ms (P=0.013), reflecting normal baroreflex response, whereas EP decreased to 267+/-19 ms (P<0.001). Shortening of EP was significantly correlated to earlier arrival of the lower body peripheral reflection wave (r2=0.46, P<0.001). ICP increased by 7+/-7 ms (P<0.001), the ICP-to-EP ratio increased from 14+/-3% (supine) to 19+/-3% (P<0.001) and the DBP-to-ICP ratio decreased by 7% (P=0.023). These results suggest that orthostasis decreases left ventricular output as a result of arterial wave reflections and, presumably, reduced cardiac preload. We conclude that CA ultrasound and pulse wave analysis enable noninvasive quantification of ventriculoarterial responses to changes in posture.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Regulation of Pulse

