Related Experiment Video
Updated: Jul 16, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography
T Schlosser1, O K Mohrs, A Magedanz
1Department of Diagnostic and Interventional Radiology, University of Essen, Hufelandstrasse 55, D-45122 Essen, Germany. thomas.schlosser@uni-essen.de
Purpose:
To quantify left ventricular function and mass derived from retrospectively ECG-gated 64-detector-row computed tomography coronary angiography data sets in comparison to cine magnetic resonance (MR) imaging as the reference standard. We hypothesized that the administration of beta-blockers prior to multidetector computed tomography (MDCT) coronary angiography has a significant impact on left ventricular functional parameters.
Material And Methods:
Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 21 patients (16 male, five female; age range 41-75 years, mean 64.3+/-6.8 years) referred for CT coronary angiography. Patients whose heart rates exceeded 60 bpm received 5 mg bisoprolol orally 1 hour before the MDCT examination. In case of insufficient heart-rate reduction, up to four vials (20 mg) of metoprolol were injected intravenously. The end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and left ventricular mass (LVM) of the reformatted images were analyzed compared to volumetric measurements based on continuous short-axis steady-state free-precession cine MR sequences (TR 3 ms, TE 1.5 ms, FA 60 degrees ).
Results:
On average, each patient received 15.5 mg metoprolol (range 0-20 mg) and 3.85 mg bisoprolol (range 0-5 mg). The mean heart rate was 56+/-5 bpm during CT and 73+/-9 bpm during MRI examination. This difference was statistically significant (P<0.05). Mean EDV and ESV measured on MDCT were significantly higher compared to MR (MDCT vs. MR: EDV 164.2+/-52.5 vs. 144.2+/-46.7 ml, ESV 77.3+/-46.6 vs. 63.8+/-47.3 ml; P<0.05). Mean EF and CO derived from MDCT images were significantly lower compared to MR (MDCT vs. MR: EF 55.4+/-11.8 vs. 59.3+/-15.4%, CO 4822+/-779 vs. 5755+/-1267 ml; P<0.05). Mean SV and LVM were not significantly different between both methods (MDCT vs. MR: SV 86.8+/-18.1 vs. 80.3+/-15.6 ml, P = 0.44; LVM 132.4+/-42.5 vs. 138.7+/-39.1 g, P = 0.31).
Conclusion:
Left ventricular volumes assessed by the newest-generation MDCT scanners are significantly higher compared with MRI, whereas ejection fraction and cardiac output are significantly lower in MDCT. This appears to be a result of the frequent application of beta-blockers prior to MDCT examinations.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Acute Coronary Syndrome III: Diagnostic Studies