Related Experiment Video
Updated: Jul 16, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
A software engine to justify the conclusions of an expert system for detecting renal obstruction on 99mTc-MAG3 scans
Ernest V Garcia1, Andrew Taylor, Daya Manatunga
1Department of Radiology, Emory University School of Medicine, Atlanta, Georgia 30322, USA. Ernest.Garcia@emoryhealthcare.org
Unlabelled:
The purposes of this study were to describe and evaluate a software engine to justify the conclusions reached by a renal expert system (RENEX) for assessing patients with suspected renal obstruction and to obtain from this evaluation new knowledge that can be incorporated into RENEX to attempt to improve diagnostic performance.
Methods:
RENEX consists of 60 heuristic rules extracted from the rules used by a domain expert to generate the knowledge base and a forward-chaining inference engine to determine obstruction. The justification engine keeps track of the sequence of the rules that are instantiated to reach a conclusion. The interpreter can then request justification by clicking on the specific conclusion. The justification process then reports the English translation of all concatenated rules instantiated to reach that conclusion. The justification engine was evaluated with a prospective group of 60 patients (117 kidneys). After reviewing the standard renal mercaptoacetyltriglycine (MAG3) scans obtained before and after the administration of furosemide, a masked expert determined whether each kidney was obstructed, whether the results were equivocal, or whether the kidney was not obstructed and identified and ranked the main variables associated with each interpretation. Two parameters were then tabulated: the frequency with which the main variables associated with obstruction by the expert were also justified by RENEX and the frequency with which the justification rules provided by RENEX were deemed to be correct by the expert. Only when RENEX and the domain expert agreed on the diagnosis (87 kidneys) were the results used to test the justification.
Results:
RENEX agreed with 91% (184/203) of the rules supplied by the expert for justifying the diagnosis. RENEX provided 103 additional rules justifying the diagnosis; the expert agreed that 102 (99%) were correct, although the rules were considered to be of secondary importance.
Conclusion:
We have described and evaluated a software engine to justify the conclusions of RENEX for detecting renal obstruction with MAG3 renal scans obtained before and after the administration of furosemide. This tool is expected to increase physician confidence in the interpretations provided by RENEX and to assist physicians and trainees in gaining a higher level of expertise.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Imaging Studies II: Ultrasonography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...