Related Experiment Video
Updated: Jul 16, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Transient overdrive pacing upon standing prevents orthostatic hypotension in elderly pacemaker patients with
Hung-Fat Tse1, Chu-Pak Lau, Euljoon Park
1Cardiology Division, Department of Medicine, The University of Hong Kong, Queen Mary Hospital, Hong Kong, China. hftse@hkucc.hku.hk
Background:
Elderly pacemaker patients with chronotropic incompetence (CI) may experience orthostatic hypotension (OH) upon standing. The objective of this study was to determine whether a transient increase in heart rate (HR) by overdrive pacing upon standing prevents OH in elderly pacemaker patients.
Methods:
We studied the effect of transient overdrive pacing upon standing in mitigating the drop in blood pressure (BP) in 62 pacemaker patients (77 +/- 6 years, 32 F) implanted with DDD pacemaker for sick sinus syndrome (n = 40) or atrioventricular block (n = 22). All patients underwent two standing procedures in random order: a control, with backup (60 bpm) pacing and another with overdrive DDD pacing (at 35 bpm above their baseline rate) for 2 minutes upon standing. Systolic (SBP) and diastolic blood pressure (DBP) and HR were measured while supine (baseline) and 1, 2, and 3 minutes after standing. OH was defined as a drop in SBP > or = 20 mmHg or DBP > or = 10 mmHg during standing. Chronotropic incompetence (CI) was defined as an absence of HR increase of > or = 10 bpm during standing.
Results:
A total of 17 (27%) patients developed OH upon standing during backup pacing. Baseline clinical characteristics (age, sex, prevalence of diabetes, use of vasoactive medications, and sick sinus syndrome) were similar between patients with or without OH. In patients with or without OH, transient overdrive pacing upon standing increased HR and DBP as compared with baseline (P < 0.05). However, in patients with OH, transient overdrive pacing did not prevent decrease in SBP upon standing and avoided the development of OH in only 10/17 patients (59%). Among those patients with OH, 10/17 (59%) patients had CI. In OH patients with CI, transient overdrive pacing upon standing maintained SBP and DBP as compared to baseline and prevented OH in the majority of patients (80%). By contrast, transient overdrive pacing in OH patients without CI had no significant effect on the decrease in SBP upon standing and prevented OH in only 20% of patients.
Conclusions:
OH is common (27%) in the elderly pacemaker population. In a subgroup of these patients, CI may be responsible for the occurrence of OH, and OH can be prevented by transient overdrive pacing upon standing.
Related Concept Videos
Heart Failure Drugs: Inotropic Agents
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with bradycardia...
Pharmacodynamics in Geriatric Patients: Effects of Age
Heart Failure Drugs: β-Blockers
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...