Arterial and central venous pressure monitoring
Atilio Barbeito1, Jonathan B Mark
1Department of Anesthesiology, Duke University Medical Center, Box 3094, Durham, NC 27710, USA.
Abstract:
Pressure monitoring systems influence the contour of the displayed wave-forms and, on occasion, can introduce significant artifact in the pressure traces. It is important to understand the technical details of invasive pressure monitoring to interpret better the information presented. Careful observation of the arterial pressure waveform can provide information about ventricular function, the arterial system, and ventricular preload. In particular, systolic pressure variation during the respiratory cycle in mechanically ventilated patients is a clinically useful indicator of volume status. CVP monitoring is also used to assess intravascular volume, but this measurement is significantly influenced by ventricular compliance and intrathoracic pressure. Under most clinical circumstances, a trend in CVP values or its change with therapeutic maneuvers is more reliable than a single measurement. Like arterial pressure waveforms, CVP waveform morphology can provide important information about clinical pathophysiology.
Related Concept Videos
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Catheterization II: Right Heart Catheterization
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...