Related Experiment Video
Updated: Jul 16, 2026

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical
Eric J W Liou1, Po-Hsun Chen, Yu-Chih Wang
1Department of Orthodontics and Craniofacial Dentistry, Chang Gung Memorial Hospital, Taipei, Taiwan. lioueric@ms19.hinet.net
Introduction:
The purpose of this study was to measure the thickness of the infrazygomatic (IZ) crest above the maxillary first molar at different angles and positions to the maxillary occlusal plane. These measurements were then used to derive clinical implications and guidance for inserting miniscrews in the IZ crest without injuring the mesiobuccal root of the maxillary first molar.
Methods:
Computed tomographic images of 16 adults were used. For each subject, on the coronal slice of the computed tomographic image containing the IZ crest and mesiobuccal root of the maxillary first molar, the IZ crest thickness and the miniscrew insertion position were measured by postulating that the miniscrew would be inserted at each 5 degrees increment from 40 degrees to 75 degrees to the maxillary occlusal plane.
Results:
The IZ crest thickness above the maxillary first molar ranged from 5.2 +/- 1.1 mm to 8.8 +/- 2.3 mm, measured at 40 degrees to 75 degrees to the maxillary occlusal plane and 13 to 17 mm above the maxillary occlusal plane.
Conclusions:
By adopting 6 mm as the minimal IZ crest thickness for sustaining a miniscrew well throughout treatment and avoiding injury to the mesiobuccal root of the maxillary first molar, the clinical implication for miniscrew placement in the IZ crest of an adult is to insert it 14 to 16 mm above the maxillary occlusal plane and the maxillary first molar at an angle of 55 degrees to 70 degrees to the maxillary occlusal plane.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
