Inactivation of Norovirus by ozone gas in conditions relevant to healthcare
J B Hudson1, M Sharma, M Petric
1Viroforce Systems Inc. Laboratory, Vancouver, Canada. jbhudson@interchange.ubc.ca
Abstract:
We evaluated the ability of ozone gas to inactivate Norovirus and its animal surrogate feline calicivirus (FCV) in dried samples placed at various locations within a hotel room, a cruise liner cabin and an office. Norovirus was measured by quantitative reverse transcriptase real-time polymerase chain reaction (QRT-PCR) assay, and FCV by a combination of QRT-PCR and virus infectivity assays. We were able to reduce the concentration of infectious FCV by a factor of more than 10(3), and in some cases beyond detection, under optimal conditions of ozone exposure with less than an hour of total operation. QRT-PCR assays indicated similar decreases in both viral RNAs. Virus-containing samples dried onto hard surfaces (plastic, steel and glass), and soft surfaces such as fabric, cotton and carpet, were equally vulnerable to the treatment. Our results show that Norovirus can be inactivated by exposure to ozone gas from a portable commercial generator in settings such as hotel rooms, cruise ship cabins and healthcare facilities.
More Related Videos
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Hand hygiene
Hand washing...