Related Experiment Video
Updated: Jul 16, 2026

15N CPMG Relaxation Dispersion for the Investigation of Protein Conformational Dynamics on the µs-ms Timescale
Published on: April 19, 2021
Nonuniform sampling and maximum entropy reconstruction applied to the accurate measurement of residual dipolar
Jayne A Kubat1, James J Chou, David Rovnyak
1Bucknell University, Department of Chemistry, Lewisburg, PA 17837, USA.
Abstract:
Residual dipolar couplings (RDC) provide important global restraints for accurate structure determination by NMR. We show that nonuniform sampling in combination with maximum entropy reconstruction (MaxEnt) is a promising strategy for accelerating and potentially enhancing the acquisition of RDC spectra. Using MaxEnt-processed spectra of nonuniformly sampled data sets that are reduced up to one fifth relative to uniform sampling, accurate 13C'-13Calpha RDCs can be obtained that agree with an RMS of 0.67 Hz with those derived from uniformly sampled, Fourier transformed spectra. While confirming that frequency errors in MaxEnt spectra are very slight, an unexpected class of systematic errors was found to occur in the 6th significant figure of 13C' chemical shifts of doublets obtained by MaxEnt reconstruction. We show that this error stems from slight line shape perturbations and predict it should be encountered in other nonlinear spectral estimation algorithms. In the case of MaxEnt reconstruction, the error can easily be rendered systematic by straightforward optimization of MaxEnt reconstruction parameters and self-cancels in obtaining RDCs from nonuniformly sampled, MaxEnt reconstructed spectra.
More Related Videos
14:55Atomic Scale Structural Studies of Macromolecular Assemblies by Solid-state Nuclear Magnetic Resonance Spectroscopy
Published on: September 17, 2017
07:24Paramagnetic Relaxation Enhancement for Detecting and Characterizing Self-Associations of Intrinsically Disordered Proteins
Published on: September 23, 2021
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution