Related Experiment Video
Updated: Jul 16, 2026

An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach
Published on: December 7, 2016
Segmentation of the surfaces of the retinal layer from OCT images
Mona Haeker1, Michael Abràmoff, Randy Kardon
1Department of Electrical and Computer Engineering, The University of Iowa, Iowa City, IA 52242, USA. mona-haeker@uiowa.edu
Abstract:
We have developed a method for the automated segmentation of the internal limiting membrane and the pigment epithelium in 3-D OCT retinal images. Each surface was found as a minimum s-t cut from a geometric graph constructed from edge/regional information and a priori-determined surface constraints. Our approach was tested on 18 3-D data sets (9 from patients with normal optic discs and 9 from patients with papilledema) obtained using a Stratus OCT-3 scanner. Qualitative analysis of surface detection correctness indicates that our method consistently found the correct surfaces and outperformed the proprietary algorithm used in the Stratus OCT-3 scanner. For example, for the internal limiting membrane, 4% of the 2-D scans had minor failures with no major failures using our approach, but 19% of the 2-D scans using the Stratus OCT-3 scanner had minor or complete failures.