Bayesian analysis supports use of ambulatory blood pressure monitors for screening
1Department of Medicine, Mount Sinai School of Medicine, New York, N.Y. 10029.
Abstract:
To assess whether there is a role for ambulatory blood pressure monitoring (ABPM) in screening for hypertension, we conducted Bayesian analysis of office blood pressure (OBP) as a diagnostic "test" in populations with different prior probabilities (PP) of hypertension. OBP was considered a positive test if systolic blood pressure was greater than 140 mm Hg or diastolic pressure was greater than 90 mm Hg. Chosen daytime ABPM cutoffs for a "gold standard" diagnosis of hypertension were systolic pressure of 139 and diastolic pressure of 88 mm Hg. Sensitivity and specificity of OBP were determined in 72 patients with established hypertension (PP = 1). After 3 weeks off therapy, OBP was 168 +/- 3/101 +/- 1 and ABPM was 151 +/- 2/94 +/- 1 mm Hg. Systolic ABPM was in the normotensive range in 17 patients and diastolic in 15 patients. OBP was falsely positive in 14 and 15 of these patients, respectively. Thus, sensitivity and specificity of OBP were 0.8909 and 0.1765 (systolic) and 0.9825 and 0 (diastolic). These data cannot be extrapolated to populations with lower PPs for use of Bayes' theorem. Hence, we calculated sensitivity and specificity for PP = 0 from published series of ABPM in normotensive subjects and used our measurements and these calculations in arithmetic interpolations for populations with PP 0.1-0.9. Sigmoid relations between PP and predictability of hypertension by a positive OBP were disclosed by use of Bayes' theorem. Their best-fit cubic polynomials predict that an elevated OBP will misdiagnose hypertension 46-50% of the time in a general population (PP = 0.2) but only 8-9% in a specialty practice (PP = 0.9).(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure