Related Experiment Video
Updated: Jul 16, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
In vivo time-resolved reflectance spectroscopy of the human forehead
Daniela Comelli1, Andrea Bassi, Antonio Pifferi
1Centre of Ultrafast and Ultraintense Optical Science, Consiglio Nazionale delle Ricerche, Istituto Nazionale de Fisica della Materia, Politecnico di Milano, Milano, Italy. daniela.comelli@polmi.it
Abstract:
We present an in vivo broadband spectroscopic characterization of the human forehead. Absorption and scattering properties are measured on five healthy volunteers at five different interfiber distances, using time-resolved diffuse spectroscopy and interpreting data with a model of the diffusion equation for a homogeneous semi-infinite medium. A wavelength-tunable mode-locked laser and time-correlated single-photon counting detection are employed, enabling fully spectroscopic measurements in the range of 700-1000 nm. The results show a large variation in the absorption and scattering properties of the head depending on the subject, whereas intrasubject variations, assessed at different interfiber distances, appear less relevant, particularly for what concerns the absorption coefficient. The high intersubject variability observed indicates that a unique set of optical properties for modeling the human head cannot be used correctly. To better interpret the results of the analysis of in vivo measurements, we performed a set of four-layer model Monte Carlo simulations based on different data sets for the optical properties of the human head, partially derived from the literature. The analysis indicated that, when simulated time-resolved curves are fitted with a homogeneous model for the photon migration, the retrieved absorption and reduced scattering coefficients are much closer to superficial layer values (i.e., scalp and skull) than to deeper layer ones (white and gray matter). In particular, for the shorter interfiber distances, the recovered values can be assumed as a good estimate of the optical properties of the first layer.
More Related Videos
07:06Simultaneous Evaluation of Cerebral Hemodynamics and Light Scattering Properties of the In Vivo Rat Brain Using Multispectral Diffuse Reflectance Imaging
Published on: May 7, 2017
06:50Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017