Empirical model functions to calculate hematocrit-dependent optical properties of human blood
Martina Meinke1, Gerhard Müller, Jürgen Helfmann
1Institut für Medizinische Physik and Lasermedizin, Campus Benjamin Franklin, Charité-Universitätsmedizin, Berlin, Germany. martina.meinke@charite.de
Abstract:
The absorption coefficient, scattering coefficient, and effective scattering phase function of human red blood cells (RBCs) in saline solution were determined for eight different hematocrits (Hcts) between 0.84% and 42.1% in the wavelength range of 250-1100 nm using integrating sphere measurements and inverse Monte Carlo simulation. To allow for biological variability, averaged optical parameters were determined under flow conditions for ten different human blood samples. Based on this standard blood, empirical model functions are presented for the calculation of Hct-dependent optical properties for the RBCs. Changes in the optical properties when saline solution is replaced by blood plasma as the suspension medium were also investigated.
Related Concept Videos
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Model Approaches for Pharmacokinetic Data: Physiological Models
Pharmacokinetic Models: Overview
There are three primary types of models: empirical, compartment, and physiological. Empirical models, with minimal assumptions,...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Physiological Pharmacokinetic Models: Assumption with Protein Binding
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...