Related Experiment Video
Updated: Jul 16, 2026

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
On the complex three-dimensional amplitude point spread function of lenses and microscope objectives: theoretical
A Marian1, F Charrière, T Colomb
1Ecole Polytechnique Fédérale de Lausanne (EPFL), Imaging and Applied Optics Institute, Station 17, CH-1015 Lausanne, Switzerland.
Abstract:
The point spread function is widely used to characterize the three-dimensional imaging capabilities of an optical system. Usually, attention is paid only to the intensity point spread function, whereas the phase point spread function is most often neglected because the phase information is not retrieved in noninterferometric imaging systems. However, phase point spread functions are needed to evaluate phase-sensitive imaging systems and we believe that phase data can play an essential role in the full aberrations' characterization. In this paper, standard diffraction models have been used for the computation of the complex amplitude point spread function. In particular, the Debye vectorial model has been used to compute the amplitude point spread function of x63/0.85 and x100/1.3 microscope objectives, exemplifying the phase point spread function specific for each polarization component of the electromagnetic field. The effect of aberrations on the phase point spread function is then analyzed for a microscope objective used under nondesigned conditions, by developing the Gibson model (Gibson & Lanni, 1991), modified to compute the three-dimensional amplitude point spread function in amplitude and phase. The results have revealed a novel anomalous phase behaviour in the presence of spherical aberration, providing access to the quantification of the aberrations. This work mainly proposes a method to measure the complex three-dimensional amplitude point spread function of an optical imaging system. The approach consists in measuring and interpreting the amplitude point spread function by evaluating in amplitude and phase the image of a single emitting point, a 60-nm-diameter tip of a Near Field Scanning Optical Microscopy fibre, with an original digital holographic experimental setup. A single hologram gives access to the transverse amplitude point spread function. The three-dimensional amplitude point spread function is obtained by performing an axial scan of the Near Field Scanning Optical Microscopy fibre. The phase measurements accuracy is equivalent to lambda/60 when the measurement is performed in air. The method capability is demonstrated on an Achroplan x20 microscope objective with 0.4 numerical aperture. A more complete study on a x100 microscope objective with 1.3 numerical aperture is also presented, in which measurements performed with our setup are compared with the prediction of an analytical aberrations model.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Three-Dimensional Microscopy in Microbiology
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

