Related Experiment Video
Updated: Jul 16, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
A combined method for the determination of myocardial perfusion in experimental animals using microspheres and CMR
Pál Surányi1, Pál Kiss, Tamás Simor
1The Department of Biochemistry, Molecular Genetics University of Alabama, Birmingham, Alabama 35294-0005, USA.
Abstract:
A convenient method is introduced for myocardial perfusion research by combining multislice short-axis cine cardiovascular magnetic resonance (MSA-CMR) and colored microspheres (CM). In canine control-ischemia-reperfusion (n = 11), Cardiac output (CO) was measured using MSA-CMR (COMSA), Phase Contrast CMR (PC-CMR, COPC) and CM (from reference blood samples, COmicro) in 3 experimental periods per animal. COmicro significantly and systematically overestimated COMSA (median deviation: 291 mL/min, p < 0.01), while there was excellent agreement between PC-CMR and MSA-CMR without significant over-or underestimation (median deviation: -14 ml/min, p = NS). In quantitative myocardial perfusion assay by CM, CMR should be used instead of reference blood sampling. This should improve the accuracy of absolute regional perfusion measurement.