Related Experiment Video
Updated: Jul 16, 2026

A Simplified Stepwise Approach to Echo Guidance during Percutaneous Mitral Valve Repair
Published on: October 16, 2021
Mitral Omnicarbon monoleaflet valve dehiscence mapped by 3D echocardiography
Leyla Elif Sade1, Melek Uluçam, Haldun Müderrisoğlu
1University of Başkent, Faculty of Medicine, Department of Cardiology, Ankara, Turkey. sadele@gmail.com
Abstract:
A patient with a prosthetic mitral valve presented with dyspnea, a new murmur and anemia. Real time three-dimensional (3D) echocardiography revealed a large valvular dehiscence that spanned approximately 50% of the circumference of the valve ring. By transesophageal echocardiography the paravalvular leak was mapped between 60 and 180 degrees that exactly matched the 3D echocardiographic appearance.