Related Experiment Video
Updated: Jul 16, 2026

Disruption of the Mouse Blood-Brain Barrier by Small Extracellular Vesicles from Hypoxic Human Placentas
Published on: January 26, 2024
Values of certain clinical and biochemical tests for prediction of pre-eclampsia
M H Soltan1, Z A Ismail, S M Kafafi
1Departments of Obstetrics and Gynecology, and Clinical Pathology, El-Menia and Ain Shams Universities, Egypt.
To evaluate different predictive tests for pre-eclampsia, either individually or in combination, we prospectively studied 100 primigravid females. Eighty-eight of the subjects continued the follow-up until delivery and 17 developed pre-eclampsia. Venous blood samples were take for determination of plasma fibronectin, and urine samples were taken for determination of microalbuminaria and calcium-creatinine ratio. Isometric handgrip exercise tests were also performed. Evaluation of predictive tests, as well as t and chi-squared statistical tests, were used for analysis of data. Pre-eclampsia developed in 19.3% of the patients studied. Pre-eclamptic and normotensive females showed significant differences in calcium-creatinine ratio and plasma fibronectin levels in both ( 14-24 weeks and 28-32 weeks) gestation periods (P <.0001). Plasma fibronectin had the best sensitivity, positive, and negative values in gestation period 14-24 weeks, whereas isometric handgrip exercise tests had the best specificity. These values improved for all the tests in the 28-32-week gestation period; even so, plasma fibronectin proved best of all. A combination of tests failed to improve the predictive ability of fibronectin alone. We conclude that plasma fibronectin is the best predictive test for pre-eclampsia.
To evaluate different predictive tests for pre-eclampsia, either individually or in combination, we prospectively studied 100 primigravid females. Eighty-eight of the subjects continued the follow-up until delivery and 17 developed pre-eclampsia. Venous blood samples were take for determination of plasma fibronectin, and urine samples were taken for determination of microalbuminaria and calcium-creatinine ratio. Isometric handgrip exercise tests were also performed. Evaluation of predictive tests, as well as t and chi-squared statistical tests, were used for analysis of data. Pre-eclampsia developed in 19.3% of the patients studied. Pre-eclamptic and normotensive females showed significant differences in calcium-creatinine ratio and plasma fibronectin levels in both ( 14-24 weeks and 28-32 weeks) gestation periods (P <.0001). Plasma fibronectin had the best sensitivity, positive, and negative values in gestation period 14-24 weeks, whereas isometric handgrip exercise tests had the best specificity. These values improved for all the tests in the 28-32-week gestation period; even so, plasma fibronectin proved best of all. A combination of tests failed to improve the predictive ability of fibronectin alone. We conclude that plasma fibronectin is the best predictive test for pre-eclampsia.
Related Concept Videos
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Serum Studies: Renal Function Tests