Related Experiment Video
Updated: Jul 16, 2026

Invasive Hemodynamic Assessment for the Right Ventricular System and Hypoxia-Induced Pulmonary Arterial Hypertension in Mice
Published on: October 24, 2019
Radial pressure waveform dP/dt max is a poor indicator of left ventricular systolic function
J E Sharman1, A M Qasem, L Hanekom
1Department of Medicine and School of Movement Studies, University of Queensland, Princess Alexandra Hospital, Ipswich Road, Wooloongabba, Brisbane, Queensland 4102, Australia. jsharman@soms.uq.edu.au
Background:
The first derivative of left ventricular (LV) pressure over time (dP/dt max) is a marker of LV systolic function that can be assessed during cardiac catheterization and echocardiography. Radial artery dP/dt max has been proposed as a possible marker of LV systolic function and we sought to test this hypothesis.
Materials And Methods:
We compared simultaneously recorded radial dP/dt max (by high-fidelity tonometry) with LV dP/dt max (by high-fidelity catheter and echocardiography parameters analogous to LV dP/dt max). In study 1, beat-to-beat radial dP/dt max and LV dP/dt max were recorded at rest and during supine exercise in 12 males (aged 61 +/- 12 years) undergoing cardiac catheterization. In study 2, 2D-echocardiography and radial dP/dt max were recorded in 54 patients (separate to study 1; 39 men; aged 64 +/- 10 years) at baseline and peak dobutamine-induced stress. Three basal septum measures were taken as being analogous to LV dP/dt max: 1. Peak systolic strain rate; 2. Strain rate (SR-dP/dt max) during isovolumic contraction (IVCT) and; 3. Tissue velocity during IVCT.
Results:
In study 1 there was a significant difference between resting LV dP/dt max (1461 +/- 383 mmHg s(-1)) and radial dP/dt max (1182 +/- 319 mmHg s(-1); P < 0.001), and a poor, but statistically significant, correlation between the variables (R(2) = 0.006; P < 0.05). Similar results were observed during exercise. In study 2 there were weak (R(2) = -0.12; P = 0.01) to non-significant associations between radial dP/dt max and all echocardiographic measures analogous to LV dP/dt max at rest or peak stress.
Conclusion:
Radial pressure waveform dP/dt max is not a reliable marker of LV systolic function.
More Related Videos
08:57Pulsed Wave Doppler Assessment of Diastolic Dysfunction in the ZSF-1 Rat Model of Pulmonary Hypertension Due to Left Heart Disease
Published on: May 22, 2026
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Blood Pressure
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement