Related Experiment Video
Updated: Jul 16, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Quantification of the intensity of virgin olive oil sensory attributes by direct coupling headspace-mass spectrometry
S López-Feria1, S Cárdenas, J A García-Mesa
1Department of Analytical Chemistry, Marie Curie Building (Annex), Campus de Rabanales, University of Córdoba, E-14071, Spain.
Abstract:
The main sensory defects of virgin olive oils (rancid, vinegary, winey, muddy sediment, musty and vegetable water) and one positive attribute (fruity) characteristic of three monovarietal extra virgin olive oils (Arbequina, Picual and Frantoio) have been quantified using the direct coupling headspace-mass spectrometry. The results obtained were compared with those provided by the panel test for the same samples. Taking into account that no chromatographic separation exists, multivariate calibration techniques (partial least squares, PLS, and principal components regression, PCR) were used to create the appropriate models. The best results, in terms of standard error of prediction and prediction residual error sum of squares were obtained by PLS and therefore it was used for the prediction of a new set of samples with the above-mentioned positive and negative attributes at different concentration levels. The samples were also assessed by the panel test and good correlations were obtained in all cases. In order to extend the applicability of the model with the time, a multiplicative calibration transfer was used. The benefit of this approach was found to be more marked for the negative than the positive attributes.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometers
Mass Spectrometry: Overview
UV–Vis Spectrometers
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
High-Resolution Mass Spectrometry (HRMS)