Related Experiment Video
Updated: Jul 16, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Agreement of measures obtained radiographically and by the OSI CA-6000 Spine Motion Analyzer for cervical spinal
Cheryl M Petersen1, Dale Schuit, Robert D Johnson
1Department of Physical Therapy, Concordia University Wisconsin, 12800 North Lake Shore Drive, Mequon, WI 53097, USA. cheryl.petersen@cuw.edu
Abstract:
The purpose of this study was to determine the agreement between angular measures of cervical spinal motion obtained from radiographs and from measures recorded by the OSI CA 6000 Spine Motion Analyzer (OSI SMA) in asymptomatic subjects. Fourteen subjects performed each of the following motions two times while wearing the OSI SMA: cervical flexion, extension, side bending to the right and left. Each motion was performed once for the cervical radiograph. The difference between the values obtained by the two methods was plotted against the average of those values for each subject to illustrate the level of agreement of the two methods. The plotted points were widely scattered, with a large range between the limits of agreement. Range of motion values taken from the OSI SMA were not similar to those obtained from radiographs for the motions of the cervical spine.