Related Experiment Video
Updated: Jul 16, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Monitoring renal function: a prospective study comparing camera-based technetium-99m mercaptoacetyltriglycine
Raghuveer Halkar1, Andrew Taylor, Amita Manatunga
1Department of Radiology, Emory University School of Medicine and Veterans Affairs Medical Center, Atlanta, Georgia, USA.
Objectives:
To determine the value and limitations of technetium-99m mercaptoacetyltriglycine (MAG3) clearance measurements obtained using a gamma camera (camera-based MAG3 clearance), a prospective study was conducted to evaluate the reproducibility of camera-based MAG3 clearance compared with that of conventional creatinine clearance.
Methods:
A total of 24 male patients with stable renal function were entered into the study. The mean age was 66.5 +/- 7.9 years, and the mean serum creatinine was 1.38 +/- 0.57 mg/dL. MAG3 renal scans and 24-hour creatinine clearance measurements were performed 11 +/- 8 days apart. A camera-based MAG3 clearance was obtained at each MAG3 scan; no blood samples were required. Bland-Altman plots were constructed to assist in data analysis.
Results:
The Pearson correlation for the first and second camera-based MAG3 clearances (mean 151 versus 158 mL/min/1.73 m2, respectively) was 0.965 compared with 0.729 for the two creatinine clearance measurements (mean 62 versus 72 mL/min/1.73 m2, respectively). Even with the omission of two outliers, the creatinine clearance would have to change by 58.2% compared with the baseline measurement before the clinician could be confident the change exceeded the error of measurement. In contrast, the change required for the camera-based MAG3 clearance was 30.8%.
Conclusions:
The results of this study have demonstrated that MAG3 clearance obtained using a camera-based technique shows greater precision than the conventional creatinine clearance and is superior to the conventional creatinine clearance for monitoring changes in renal function.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Imaging Studies III: Computed Tomography
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...

