Extrapleural intrathoracic implantation of permanent pacemaker in the pediatric age group
Ravi Agarwal1, Ganapathy Subramaniam Krishnan, Smartin Abraham
1Department of Pediatric Cardiac Surgery, International Center for Cardiothoracic and Vascular Diseases, Chennai, Tamilnadu, India.
Abstract:
Permanent pacemaker implantation in pediatric patients poses challenges in finding a suitable pocket for generator implantation. We present our experience with 6 patients in whom the pacemaker was placed in an extrapleural intrathoracic location. We find that an extrapleural intrathoracic pocket is a useful site for generator placement in the neonatal and pediatric age group. It is safe, reproducible, and both the lead and generator can be placed through a single incision. We briefly discuss the advantages and disadvantages of other techniques that require a single incision for both lead and generator placement.