Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Measurement of local pulse wave velocity: effects of signal processing on precision
Evelien Hermeling1, Koen D Reesink, Robert S Reneman
1Department of Biophysics, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Abstract:
Pulse wave velocity (PWV) provides information about the mechanical properties of the vessel: the stiffer the artery is, the higher the PWV will be. PWV measured over a short arterial segment facilitates direct characterization of local wall properties corrected for prevailing pressure without the necessity of measuring pulse pressure locally. Current methods for local PWV assessment have a poor precision, but it can be improved by applying linear regression to a characteristic time-point in distension waveforms as recorded simultaneously by multiple M-line ultrasounds. We investigated the precision of this method in a phantom scaled according to realistic in vivo conditions. Special attention was paid to the identification of the foot of the wave, using the maximum of the second derivative, the intersecting tangent and the 20% threshold method. Before foot detection, the distension waveforms were subjected to preprocessing with various filters. The precision of the maximum of the second derivative had a coefficient of variation (CV) of 0.45% and 10.45% for an eighth and second order low pass filter, respectively. The intersecting tangent and the threshold method were less sensitive to filtering; the CVs were 0.66% and 0.68% for the high order filter and 2.36% and 1.43% for the low order filter, respectively. We conclude that foot detection by a threshold of 20% or by the tangent method are more suitable to identify the foot of the wave to measure local PWV. Both methods are less sensitive to (phase) noise than the maximum of the second derivative method and exhibit good precision with a CV of less than 1%.
Related Concept Videos
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: