An in vitro comparison of the force decay generated by different commercially available elastomeric chains and NiTi
Ana Cristina Soares Santos1, André Tortamano, Sandra Regina Frazatto Naccarato
1Department of Orthodontics, School of Dentistry, University of São Paulo, Rua Oscar Freire 2121-1101, Pinheiros, São Paulo, SP, Brazil, CEP 05409-011. anacssantos@usp.br
Abstract:
This in vitro study was designed to compare the forces generated by commercially available elastomeric chains and NiTi closed coil springs, and to determine their force decay pattern. Forty elastomeric chains and forty NiTi closed coil springs were divided into 4 groups according to the following manufacturers: (1) Morelli, (2) Abzil, (3) TP Orthodontics and (4) American Orthodontics. The specimens were extended to twice their original length and stored in artificial saliva at 37 degrees C. Initial force was measured by means of an Instron universal testing machine and then at 1, 4, 7, 14, 21, and 28 days. The results revealed that the elastomeric chains delivered a mean initial force of 347 g for Morelli, 351 g for American Orthodontics, 402 g for Abzil, and 404 g for TP Orthodontics. The NiTi closed coil springs generated a mean initial force of 196 g for American Orthodontics, 208 g for TP Orthodontics, 216 g for Abzil, and 223 g for Morelli. The mean percentage of force decay observed after 28 days for the elastomeric chains was 37.4% for TP Orthodontics(R), 48.1% for American Orthodontics, 65.4% for Morelli, and 71.6% for Abzil. After 28 days, the NiTi closed coil springs presented a mean percentage of force decay of 22.6% for American Orthodontics, 29.8% for Abzil, 30.6% for Morelli, and 45.8% for TP Orthodontics. At the end of the study, significant differences were observed between the elastomeric chains and the NiTi closed coil springs. The results indicated that the studied NiTi closed coil springs are more adequate for dental movement than the elastomeric chains.
Related Concept Videos
Strain and Elastic Modulus
Cell-matrix's Response to Mechanical Forces
Anchoring junctions mechanically attach a cell to the...
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used to...
Hooke's Law
Elasticity in Concrete