Combined use of endothelial function assessed by brachial ultrasound and high-sensitive C-reactive protein in

Po-Hsun Huang1, Jaw-Wen Chen, Tse-Min Lu

  • 1Division of Cardiology, Department of Internal Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.

Clinical Cardiology
|March 28, 2007
PubMed

Insights

Assessing endothelial function and high-sensitive C-reactive protein (hsCRP) together improves prediction of cardiovascular events. Combining flow-mediated vasodilation (FMD) and hsCRP offers significant risk stratification for patients with suspected coronary artery disease.

Area of Science:

  • Cardiology
  • Vascular Biology
  • Biomarkers

Background:

  • Endothelial dysfunction is crucial in atherosclerosis development.
  • Elevated high-sensitive C-reactive protein (hsCRP) indicates poor cardiovascular prognosis.

Purpose of the Study:

  • To evaluate if combining endothelial function and hsCRP enhances prediction of future cardiovascular events.
  • To assess the combined predictive value of flow-mediated vasodilation (FMD) and hsCRP.

Main Methods:

  • Followed 205 patients for 24 months.
  • Measured endothelial function via flow-mediated vasodilation (FMD) using brachial ultrasound.
  • Utilized Cox regression analysis to identify predictors of cardiovascular events (myocardial infarction, heart failure hospitalization, PCI, CABG, ischemic stroke).

Main Results:

  • Twenty-nine patients (14%) experienced cardiovascular events.
  • Both FMD and hsCRP were significant predictors of cardiovascular events.
  • The combination of low FMD (<6%) and high hsCRP (≥1 mg/dL) showed a markedly increased risk (RR 12.598) for cardiovascular events compared to optimal levels (FMD ≥6%, hsCRP <1 mg/dL).

Conclusions:

  • Risk stratification using both endothelium-dependent FMD and hsCRP benefits patients with suspected coronary artery disease.
  • Combined assessment of FMD and hsCRP significantly contributes to predicting cardiovascular event incidence.
Abstract

Related Concept Videos

Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers01:19

Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers

Cardiac biomarkers are critical in diagnosing, prognosing, and managing cardiovascular diseases. Routine measurement of specific biomarkers such as B-type natriuretic peptide (BNP), C-reactive protein (CRP), and homocysteine (Hcy) is common practice in clinical settings to evaluate heart function and predict cardiovascular events.
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure: