Related Experiment Video
Updated: Jul 16, 2026

Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Gas-diffusion flow injection determination of Hg(II) with chemiluminescence detection
1School of Chemistry, The University of Melbourne, Victoria 3010, Australia.
Abstract:
A gas-diffusion flow injection method for the chemiluminescence detection of Hg(II) based on the luminol-H(2)O(2) reaction was developed. The analytical procedure involved the injection of Hg(II) samples and standards into a 1.50 M H(2)SO(4) carrier stream, which was subsequently merged with a reagent stream of 0.60% (w/v) SnCl(2) in 1.50 M H(2)SO(4) to reduce Hg(II) to metallic Hg. The gas-diffusion cell was thermostated at 85 degrees C to enhance the vaporisation of metallic Hg. Mercury vapour, transported across the Teflon membrane of the gas-diffusion cell into the acceptor stream containing 1.00 x 10(-4) M KMnO(4) in 0.30 M H(2)SO(4), was oxidised back to Hg(II). The acceptor stream was merged with a reagent stream containing 2.50 M H(2)O(2) in deionised water and then the combined stream was merged with another reagent stream containing 7.50 x 10(-3) M luminol in 3.00 M NaOH at a confluence point opposite to the photomultiplier tube of the detection system. The chemiluminescence intensity of the luminol-H(2)O(2) reaction was enhanced by the presence of Hg(II) in the acceptor stream. The corresponding increase was related to the original concentration of Hg(II) in the samples and standards. Under optimal conditions, the chemiluminescence gas-diffusion flow injection method was characterised by a linear calibration range between 1 microg L(-1) and 100 microg L(-1), a detection limit of 0.8 microg L(-1) and a sampling rate of 12 samples per hour. It was successfully applied to the determination of mercury in seawater and river samples.
More Related Videos
05:00Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Flame Photometry: Lab
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Photoluminescence: Applications
Flame Photometry: Overview