Development and application of immunoaffinity column chromatography for atrazine in complex sample media
Related Experiment Video
Updated: Jul 16, 2026

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
Jane C Chuang1, Jeanette M Van Emon, Randy Jones
1Battelle, Columbus, OH, USA. chuangj@battelle.org
Abstract:
A rabbit antibody immunoaffinity (IA) column procedure was evaluated as a cleanup method for the determination of atrazine in soil, sediment, and food. Four IA columns were prepared by immobilizing a polyclonal rabbit anti-atrazine antibody solution to HiTrap Sepharose columns. Atrazine was bound to the IA columns when the loading solvents were either 100% water, 2% acetonitrile in water, or 10% methanol in phosphate buffered saline (PBS). Quantitative removal of atrazine from the IA columns was achieved with elution solvents of either 70% ethanol in water, 70% methanol in water, or 100% methanol. One control column was prepared using nonspecific rabbit IgG antibody. This control column did not retain any applied atrazine indicating atrazine did not bind indiscriminately to protein or the Sepharose support. The four IA columns showed reproducible coupling efficiency for the immobilization of the atrazine antibody and consistent binding and releasing of atrazine. The coupling efficiency (4.25 mg of antibody in 1 mL of resin bed) for the four IA columns ranged from 93 to 97% with an average of 96+/-2% (2.1%). Recoveries of the 500, 50, and 5 ng mL(-1) atrazine standard solutions from the four IA columns were 107+/-7% (6.5%), 122+/-14% (12%), and 114+/-9% (8.0%) respectively, based on enzyme-linked immunosorbent assay (ELISA) data. The maximum loading was approximately 700 ng of atrazine for each IA column (approximately 0.16 microg of atrazine per mg of antibody). The IA columns could withstand 100% methanol as the elution solvent and could be reused more than 50 times with no change in performance. The IA columns were challenged with soil, sediment, and duplicate-diet food samples and effectively removed interferences from these various matrices for subsequent gas chromatography/mass spectrometry (GC/MS) or ELISA analysis. The log-transformed ELISA and GC/MS data were significantly correlated for soil, sediment and food samples although the ELISA values were slightly higher than those obtained by GC/MS. The IA column cleanup procedure coupled with ELISA analysis could be used as an alternative effective analytical method for the determination of atrazine in complex sample media such as soil, sediment, and food samples.
More Related Videos
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
Affinity Chromatography
Ion-Exchange Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Elution Process