Related Experiment Video
Updated: Jul 16, 2026

Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Zn(II) complex-based potentiometric sensors for selective determination of nitrate anion
Rakesh Kumar Mahajan1, Ravneet Kaur, Hiroyuki Miyake
1Department of Chemistry, Guru Nanak Dev University, Amritsar 143005, India. rakesh_chem@yahoo.com <rakesh_chem@yahoo.com>
Abstract:
Polymeric membranes containing new Zn(II) complexes as anion carriers were prepared for determination of nitrate anion present in water samples. Two Zn(II) complexes coordinated by neutral tetradentate ligands, N,N'-ethylene-bis(N-methyl-(S)-alanine methylamide) and N,N'-ethylene-bis(N-methyl-(S)-alanine dimethylamide), worked well as anion-selective carriers, while common phthalocyanine Zn(II) complex rarely responded to any anions. The combination of these new Zn(II) complexes with dioctylsebacate as a plasticizer particularly offered high sensing selectivity for nitrate anion. They exhibited near-Nernstian slopes in the wide linear concentration range of 5.0 x 10(-5) to 1.0 x 10(-1) M, and operated well in the wide pH range from 4 to 11 with the response time of less than 25s. The potentiometric selectivity coefficients were evaluated using the fixed interference method, indicating that the two Zn(II) complexes exhibited better selectivity for nitrate anion with respect to a wide variety of inorganic anions. Although chloride anion worked as an interfering species at a concentration higher than 1.0 x 10(-3) M, the new Zn(II) complex-based sensors were applicable in determination of the nitrate anion after adding silver sulfate to remove the chloride anion.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
08:25Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometric Titration: Overview
Potentiometry: Overview
Complexometric Titration: Ligands
Inorganic Nitrogen Assimilation
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.