Determination of trace trichlorfon by high performance liquid chromatography with UV detection based on its catalytic

Hai-Zhen Zhu1, Yan-Mei Cui, Xiu-Wen Zheng

  • 1College of Science, Nanjing Agricultural University, Nanjing, Jiangsu Province 210095, People's Republic of China.

Analytica Chimica Acta
|March 28, 2007
PubMed

Related Concept Videos

Reactions at the Benzylic Position: Halogenation01:11

Reactions at the Benzylic Position: Halogenation

Benzylic halogenation takes place under conditions that favor radical reactions such as heat, light, or a free radical initiator like peroxide.
Hydrolysis of Chlorobenzene to Phenol: Dow Process01:10

Hydrolysis of Chlorobenzene to Phenol: Dow Process

Simple aryl halides do not react with nucleophiles under normal conditions. However, the reaction can proceed under drastic conditions involving high temperatures and high pressure to give the substituted products. For example, chlorobenzene is converted to phenol using aqueous sodium hydroxide at 350 °C under high pressure by the Dow process. The reaction follows an elimination-addition mechanism involving a benzyne intermediate. Here, the chloride ion is eliminated to generate the benzyne...
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene01:13

Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene

Bromination and chlorination of aromatic rings by electrophilic aromatic substitution reactions are easily achieved, but fluorination and iodination are difficult to achieve. Fluorine is so reactive that its reaction with benzene is difficult to control, resulting in poor yields of monofluoroaromatic products. To address this, Selectfluor reagent is used as a fluorine source in which a fluorine atom is bonded to a positively charged nitrogen.
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene01:15

Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene

Chlorination and bromination are important classes of electrophilic aromatic substitutions, where benzene reacts with chlorine or bromine in the presence of a Lewis acid catalyst to give halogenated substitution products. A Lewis acid such as aluminium chloride or ferric chloride catalyzes the chlorination, and ferric bromide catalyzes the bromination reactions. During the bromination of alkenes, bromine polarizes and becomes electrophilic. However, in the bromination of benzene, the bromine...
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...