Related Experiment Video
Updated: Jul 16, 2026

Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
Deep pericardial suture vs apical suction for off-pump bypass grafting
Hasim Ustunsoy1, Hakki Kazaz, Mehmet A Celkan
1Department of Cardiovascular Surgery, Gaziantep University School of Medicine, Universite Bul Kilis yolu, Gaziantep, Turkey.
Abstract:
Hemodynamic changes during heart luxation and stabilization are major problems in off-pump coronary artery bypass surgery. The hemodynamic effects of an apical suction device were compared with those of the classic posterior pericardial suture in 45 patients with multivessel coronary disease undergoing off-pump coronary artery bypass. Mean age was 63.78 +/- 8.11 years; 31 patients were male and 14 were female. Transesophageal Doppler echocardiography was used for hemodynamic monitoring. All hemodynamic parameters were significantly better when the apical suction device was used to position the heart for anastomoses on the posterior descending and circumflex arteries.