[Usefulness of low- and medium-energy collimators in 123I-MIBG myocardial scintigraphy]

Ryoko Sakashita1, Katsuya Sugimoto, Yuko Fukuya

  • 1Department of Radiography, University of Fukui Hospital.

The heart-to-mediastinum (H/M) ratio on myocardial scintigraphy with (123)I-metaiodobenzylguanidine (MIBG) is used as a semi-quantitative index. However, the scatter from a photopeak of 529 keV on (123)I is thought to affect the H/M ratio, and collimator selection is important as well. We attempted to determine the usefulness of low- and medium-energy general purpose (LME) collimators by comparing them with low-energy high-resolution (LEHR) and medium-energy low-penetration (MELP) collimators in phantom and clinical studies. In the phantom study, we used a thoracic phantom and plastic bottles filled with (123)I-MIBG solution as upper limbs. Phantom images were acquired with LEHR, LME, and MELP collimators. Regions of interest were placed on the lung, mediastinum, heart, and liver. The average counts in the lung, coefficient of variation (CV%) in the heart, mediastinum, and liver, and H/M ratio were calculated. The H/M ratios obtained with the LEHR collimator and LME collimator were compared in a clinical study. We found that the average count in the lung measured with the LME collimator was reduced to about 30% of that obtained with the LEHR collimator in the phantom study. CV% measured with the LME collimator improved about 10% compared with that determined with the MELP collimator. The H/M ratio measured with the LME collimator was close to that measured with the MELP collimator. In the clinical study, the H/M ratios measured with the LEHR and LME collimators showed a positive relationship (y=2.1x-1.3, x; H/M with LEHR, y; H/M with LME) . LME collimators provided improved contrast and signal-to-noise ratio in evaluation of the H/M ratio on (123)I-MIBG myocardial scintigraphy.

Related Concept Videos

Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and the...
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals โ€” substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...