[Usefulness of low- and medium-energy collimators in 123I-MIBG myocardial scintigraphy]
Ryoko Sakashita1, Katsuya Sugimoto, Yuko Fukuya
1Department of Radiography, University of Fukui Hospital.
The heart-to-mediastinum (H/M) ratio on myocardial scintigraphy with (123)I-metaiodobenzylguanidine (MIBG) is used as a semi-quantitative index. However, the scatter from a photopeak of 529 keV on (123)I is thought to affect the H/M ratio, and collimator selection is important as well. We attempted to determine the usefulness of low- and medium-energy general purpose (LME) collimators by comparing them with low-energy high-resolution (LEHR) and medium-energy low-penetration (MELP) collimators in phantom and clinical studies. In the phantom study, we used a thoracic phantom and plastic bottles filled with (123)I-MIBG solution as upper limbs. Phantom images were acquired with LEHR, LME, and MELP collimators. Regions of interest were placed on the lung, mediastinum, heart, and liver. The average counts in the lung, coefficient of variation (CV%) in the heart, mediastinum, and liver, and H/M ratio were calculated. The H/M ratios obtained with the LEHR collimator and LME collimator were compared in a clinical study. We found that the average count in the lung measured with the LME collimator was reduced to about 30% of that obtained with the LEHR collimator in the phantom study. CV% measured with the LME collimator improved about 10% compared with that determined with the MELP collimator. The H/M ratio measured with the LME collimator was close to that measured with the MELP collimator. In the clinical study, the H/M ratios measured with the LEHR and LME collimators showed a positive relationship (y=2.1x-1.3, x; H/M with LEHR, y; H/M with LME) . LME collimators provided improved contrast and signal-to-noise ratio in evaluation of the H/M ratio on (123)I-MIBG myocardial scintigraphy.
The heart-to-mediastinum (H/M) ratio on myocardial scintigraphy with (123)I-metaiodobenzylguanidine (MIBG) is used as a semi-quantitative index. However, the scatter from a photopeak of 529 keV on (123)I is thought to affect the H/M ratio, and collimator selection is important as well. We attempted to determine the usefulness of low- and medium-energy general purpose (LME) collimators by comparing them with low-energy high-resolution (LEHR) and medium-energy low-penetration (MELP) collimators in phantom and clinical studies. In the phantom study, we used a thoracic phantom and plastic bottles filled with (123)I-MIBG solution as upper limbs. Phantom images were acquired with LEHR, LME, and MELP collimators. Regions of interest were placed on the lung, mediastinum, heart, and liver. The average counts in the lung, coefficient of variation (CV%) in the heart, mediastinum, and liver, and H/M ratio were calculated. The H/M ratios obtained with the LEHR collimator and LME collimator were compared in a clinical study. We found that the average count in the lung measured with the LME collimator was reduced to about 30% of that obtained with the LEHR collimator in the phantom study. CV% measured with the LME collimator improved about 10% compared with that determined with the MELP collimator. The H/M ratio measured with the LME collimator was close to that measured with the MELP collimator. In the clinical study, the H/M ratios measured with the LEHR and LME collimators showed a positive relationship (y=2.1x-1.3, x; H/M with LEHR, y; H/M with LME) . LME collimators provided improved contrast and signal-to-noise ratio in evaluation of the H/M ratio on (123)I-MIBG myocardial scintigraphy.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...