Age-related differences in the normal human cornea: a laser scanning in vivo confocal microscopy study
R L Niederer1, D Perumal, T Sherwin
1Department of Ophthalmology, Faculty of Medical and Health Sciences, The University of Auckland, Private Bag 92019, Auckland, New Zealand
Aims:
To quantify and establish baseline normative data for age-related differences in cellular and innervation density in the normal, healthy, human cornea using laser scanning in vivo confocal microscopy.
Methods:
Cross-sectional study of 85 normal subjects assessed via corneal topography and laser scanning in vivo confocal microscopy.
Results:
Mean age was 38+/-16 years (range 18-87 years) and 60% of subjects were female. Anterior keratocyte density declined by 0.9% per year (r = -0.423, p<0.001), posterior keratocyte density declined by 0.3% per year (r = -0.250, p = 0.021) and endothelial cell density declined by 0.5% per year (r = -0.615, p<0.001). Sub-basal nerve fibre density declined by 0.9% per year (r = -0.423, p<0.001). No association was observed between age and basal epithelial cell density, or between age and central corneal thickness, corneal astigmatism or horizontal corneal diameter (p>0.05). No association was observed between subject gender and corneal cell or innervation density.
Conclusions:
Using laser scanning in vivo confocal microscopy this study highlights a significant, and relatively linear, reduction in keratocyte and endothelial cell density with increasing subject age. Interestingly, corneal sub-basal nerve fibre density also significantly decreases with increasing age. In vivo laser scanning confocal microscopy provides a safe, non-invasive method for the establishment of normative data and assessment of alterations in human corneal microstructure following surgery or disease processes.