Related Experiment Video
Updated: Jul 16, 2026

Computed Tomography (CT) Guided Implantation of a Totally Implantable Venous Access Port (TIVAP) through Subclavian Vein
Published on: January 13, 2026
Right subclavian catheter perforation of the aorta due to an incorrect external landmark-guided insertion technique
Rune Haaverstad1, Peter N Latto, Nicola Vitale
1Department of Cardiothoracic Surgery, University Hospital of Wales, Cardiff, United Kingdom. rune.haaverstad@ntnu.no
Abstract:
Emergency placement of a right subclavian triple lumen silastic catheter in an obese, unstable postoperative patient caused a perforation of the aorta, resulting in sudden cardiac tamponade. Because this complication was immediately recognized and surgical decompression with suturing of the perforation in the aorta was performed, the patient survived. A standardized approach for all central venous line insertions should be emphasized for all clinicians. Use of ultrasound guidance whenever feasible is encouraged.
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Aneurysm II: Clinical Manifestations and Diagnostic Studies
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Aneurysm I: Introduction