Presumed pseudobacteremia outbreak resulting from contamination of proportional disinfectant dispenser
1Laboratoire de Bactériologie, Hôpital Universitaire du Bocage, P.O. Box PB 77908, 21079 Dijon Cedex, France.
Abstract:
Reported here are the microbiological and epidemiological details of a presumed outbreak of aerobic gram-negative bacilli infections affecting 19 hematological patients, which was traced to contaminated disinfectant. Over a 5-month period, the following organisms were isolated from the blood cultures of 19 neutropenic patients: Pseudomonas fluorescens (n = 13), Achromobacter xylosoxidans (n = 12), Comamonas testosteroni (n = 2) or Stenotrophomonas maltophilia (n = 1). The affected patients were all treated with an expensive regimen of broad-spectrum antibiotic therapy. The same bacteria were recovered from environmental samples as well as from the water pipes of an apparatus for dispensing disinfectant (didecyldimethylammonium chloride). Genotyping results indicated that many of the clinical strains were identical to strains isolated from the apparatus. It was eventually discovered that the night staff was in the habit of disinfecting the blood-culture bottles before use, thereby contaminating the bottles with bacteria contained in the disinfectant. Contamination of the apparatus resulted from faulty maintenance.
Insights
A hospital outbreak of gram-negative bacilli infections in 19 hematology patients was linked to contaminated disinfectant. Faulty maintenance and staff practices led to bacteria contaminating blood-culture bottles, causing patient infections.
Area of Science:
- Medical Microbiology
- Infectious Disease Epidemiology
- Hospital Infection Control
Background:
- Hematological patients are susceptible to infections due to neutropenia.
- Nosocomial infections pose a significant threat in healthcare settings.
- Aerobic gram-negative bacilli are common opportunistic pathogens.
Purpose of the Study:
- To investigate an outbreak of aerobic gram-negative bacilli infections in hematological patients.
- To identify the source and transmission route of the infections.
- To implement control measures to prevent future outbreaks.
Main Methods:
- Microbiological analysis of clinical isolates and environmental samples.
- Epidemiological investigation including patient data and staff interviews.
- Genotyping of bacterial strains to determine relatedness.
- Identification of the disinfectant and dispensing apparatus as the source.
Main Results:
- Nineteen neutropenic patients developed infections with Pseudomonas fluorescens, Achromobacter xylosoxidans, Comamonas testosteroni, and Stenotrophomonas maltophilia.
- The same bacteria were isolated from the disinfectant dispensing apparatus and environmental samples.
- Genotyping confirmed the link between clinical strains and environmental isolates.
- Staff disinfecting blood-culture bottles with contaminated disinfectant was the primary contamination route.
Conclusions:
- Contaminated disinfectant used for blood-culture bottles caused a nosocomial outbreak.
- Faulty maintenance of the disinfectant apparatus contributed to environmental contamination.
- Strict adherence to disinfection protocols and equipment maintenance is crucial for infection control.
More Related Videos
Related Concept Videos
Hand hygiene
Hand washing...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...