Related Experiment Video
Updated: Jul 16, 2026

Preparing Irradiated and Marked Male Aedes aegypti Mosquitoes for Release in an Operational Sterile Insect Technique Program
Published on: March 12, 2021
Evaluation using GEANT4 of the transit dose in the Tunisian gamma irradiator for insect sterilization
K Mannai1, B Askri, A Loussaief
1Unité de Recherche de Physique Nucléaire et des Hautes énergies, Département de Physique, Faculté des Sciences de Tunis, El-Manar 2092, Tunisia.
Abstract:
A simulation study of the Tunisian Gamma Irradiation Facility for sterile insects release programs has been realized using the GEANT4 Monte Carlo code of CERN. The dose was calculated and measured for high and low dose values inside the irradiation cell. The calculated high dose was in good agreement with measurements. However, a discrepancy between calculated and measured values occurs at dose levels commonly used for sterilization of insects. We argue that this discrepancy is due to the transit dose absorbed during displacement of targets from their initial position towards their irradiation position and displacement of radiation source pencils from storage towards their irradiation position. The discrepancy is corrected by taking into account the transit dose.
Related Concept Videos
Biological Effects of Radiation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration